Sample Record

Owner Lab

  • CT HQ - Sacramento Hot Mix Asphalt Laboratory

DIME Sample ID 2022-03-07-38

Project Information

Project IdentifiersProject ID: 22225
DEA: HMA-RSRCH
EFIS: HMA-RSRCH
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionIn-house research studies for FHWA on Asphalt Mixture Performance Tester (AMPT) and Cracking Tolerance Index of Asphalt Mixtures (IDEAL CT)
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date03/07/2022 Sample Unique Key38
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/07/2022
Sample typeVerification A brief description of the sample1/2" HMA
The quantity of what the sample constitutes24 boxes From where was the sample collectedSupplier
First name of sampler or witnessed byErika Last name of sampler or witnessed byGonzalez
Title of samplerTET Telephone number of sampler
Laboratory sample identification022-007 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Pleasanton Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number
Sublot number HMA Mix NumberNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2022-03-07-38-1THIS TEST HAS BEEN SUPERSEDED.
ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate Temperature
James Brewster, CT HQ - Sacramento Hot Mix Asphalt Laboratory04/05/2022Juan Gomez
Yes
04/15/2022THIS TEST HAS BEEN SUPERSEDED.
172.9 PSI or 1192.2 KPA
2022-03-07-38-2ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate TemperatureJames Brewster, CT HQ - Sacramento Hot Mix Asphalt Laboratory04/05/2022Juan Gomez
Yes
04/15/2022172.9 PSI or 1192.2 KPA Sample #2

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2022-03-07-38-1 ASTM D8225-19 (Verified)
DIME Test ID: 2022-03-07-38-2 ASTM D8225-19 (Verified)