Sample Record
Owner Labs
- CT HQ - Sacramento Materials Management Branch Field Office
- CT - Unassigned/General Field Laboratory
DIME Sample ID 2022-04-12-1
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 215456 DEA: 07293604 EFIS: 0713000238 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-405-14.3/15.8 |
| Award Date | 05/26/2021 |
| Closeout Date | 07/03/2025 |
| Work Description | CONSTRUCT AUXILIARY LANE AND WIDEN ON AND OFF RAMPS. |
| Location Description | LOS ANGELES COUNTY IN TORRANCE BETWEEN WESTERN AVENUE UNDERCROSSING AND WEST 182ND STREET |
| QA Service Level | 1 (Verified on 07/07/2021) |
Sample Information
| Sample Taken Date | 04/12/2022 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/13/2022 |
| Sample type | Quality Assurance | A brief description of the sample | 2 ft Dia Hoops ,#5 A706 rebar Gr 60 |
| The quantity of what the sample constitutes | 3 sets of #5 Hoops from lots 1,3 and 7 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Subramony | Last name of sampler or witnessed by | krishnamoorthy |
| Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | 19512014921 |
| Laboratory sample identification | QA Lots 1 ,3, and 7 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | RKR Steel Welding | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L88-002-2022 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 1100028176 |
| Hoop Manufacturer Lot Number(s) | 1, 3 and 7 - QA | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | #5 |
| Diameter of Hoop | 2'-0" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Nucor |
| Welding Company | RKR Steel Welding | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2022-04-12-1-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2022-04-12-1-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2022-04-12-1-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2022-04-12-1-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2022-04-12-1-6 CTM 670-December 2013 (Verified)
DIME Test ID: 2022-04-12-1-7 CTM 670-December 2013 (Verified)
DIME Test ID: 2022-04-12-1-8 CTM 670-December 2013 (Verified)
DIME Test ID: 2022-04-12-1-9 CTM 670-December 2013 (Verified)
DIME Test ID: 2022-04-12-1-10 CTM 670-December 2013 (Verified)