Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2022-03-29-9
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 215692 DEA: 101C8104 EFIS: 1015000038 |
|---|---|
| DIST-CO-RTE-PM | 01-MPA,MER,SJ,STA-4,5,49,88,99,etc.-Var |
| Award Date | 06/09/2021 |
| Closeout Date | 12/05/2022 |
| Work Description | BRIDGE PREVENTIVE MAINTENANCE AND ROCK SLOPE PROTECTION. |
| Location Description | MARIPOSA, MERCED, SAN JOAQUIN, AND STANISLAUS COUNTIES AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 05/17/2021) |
Sample Information
| Sample Taken Date | 03/29/2022 | Sample Unique Key | 9 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/06/2022 |
| Sample type | Quality Assurance | A brief description of the sample | A325 bolts, Nuts and Washers |
| The quantity of what the sample constitutes | 25 | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Jason | Last name of sampler or witnessed by | Gramlick |
| Title of sampler | Associate Steel Inspector | Telephone number of sampler | 510-453-7830 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Tru-fit Products of Utah | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 2022-3-01 |
|---|---|---|---|
| Heat Number(s) | NF14103416 | Nut Mfg. Lot Number(s) | 464690A |
| Washer Mfg. Lot Number(s) | 0720-528 | Bolt Specification | ASTM A325 |
| Bolt Length(s) | 2-3/4" | Nut Specification | ASTM A563 |
| Washer Specification | ASTM F436 | Finish | Plain |
| Diameter/Size | 5/8" | Bolt Mfg. Lot Number | 354201A |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2022-03-29-9-1 ASTM F606-21 (Verified)
DIME Test ID: 2022-03-29-9-2 ASTM F606-21 (Verified)
DIME Test ID: 2022-03-29-9-3 ASME B1.2-83r17 (Verified)
DIME Test ID: 2022-03-29-9-4 ASME B1.2-83r17 (Verified)
DIME Test ID: 2022-03-29-9-5 ASTM E18-20 (Verified)