Sample Record
Owner Lab
- CT D07 - Materials Field Laboratory, Unit 1953
DIME Sample ID 2022-03-12-16
Project Information
Project Identifiers | Project ID: 214671 DEA: 07303904 EFIS: 0714000044 |
---|---|
DIST-CO-RTE-PM | 07-LA-10-31.2/37.2 |
Award Date | 11/25/2020 |
Closeout Date | 10/11/2023 |
Work Description | LANE REPLACEMENT |
Location Description | LOS ANGELES COUNTY IN BALDWIN PARK AND WEST COVINA FROM 0.1 MILE EAST OF THE 10/605 SEPARATION TO 0.3 MILE WEST OF CITRUS STREET OVERCROSSING |
QA Service Level | 1 (Verified on 01/21/2021) |
Sample Information
Sample Taken Date | 03/12/2022 | Sample Unique Key | 16 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/12/2022 |
Sample type | Department Acceptance | A brief description of the sample | Concrete Test Sample |
The quantity of what the sample constitutes | 500 cu. yd. | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Philip | Last name of sampler or witnessed by | Maquiran |
Title of sampler | MREA | Telephone number of sampler | 2133581518 |
Laboratory sample identification | 22-0443 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Security Paving Batch Plant-Irwindale | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | G3-22-LRS-271 |
---|---|---|---|
The truck number from where the sample was collected | 3 | The batch plant ticket number from where the sample was collected | Transit Mixer Chute |
Concrete batch plant | The fabricator/manufacturer designation for the sample | Security Paving company | |
A detailed description of where the material sample was collected | Transit Mixer Chute at Security Paving BP | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2022-03-12-16-1 CTM 521-June 2012 (Verified)