Sample Record
Owner Lab
- CT D05 - Prunedale Field Laboratory
DIME Sample ID 2022-03-15-4
Project Information
| Project Identifiers | Project ID: 993236 DEA: 051K0504 EFIS: 0518000114 |
|---|---|
| DIST-CO-RTE-PM | 05-MON-1-55.7/55.9 |
| Award Date | 10/14/2021 |
| Closeout Date | 09/02/2022 |
| Work Description | CONSTRUCT EARTH RETAINING SYSTEM WITH CIDH PILE & STRUCTURAL CONCRETE. |
| Location Description | MONTEREY COUNTY NEAR LITTLE SUR RIVER FROM 0.4 MILE SOUTH OF LITTLE SUR RIVER BRIDGE TO 0.2 MILE SOUTH OF LITTLE SUR RIVER BRIDGE |
| QA Service Level | 1 (Verified on 10/06/2021) |
Sample Information
| Sample Taken Date | 03/15/2022 | Sample Unique Key | 4 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/17/2022 |
| Sample type | Quality Assurance | A brief description of the sample | 3 - 4x8" Concrete Cylinders |
| The quantity of what the sample constitutes | 32 CY | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Haro | Last name of sampler or witnessed by | Pedro |
| Title of sampler | RMA QC | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Las Animas, Marina CA | Transportation Laboratory (TL) Number | 255905 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | M853P50S |
|---|---|---|---|
| The truck number from where the sample was collected | 33 | The batch plant ticket number from where the sample was collected | 201109 |
| Concrete batch plant | Las Animas Concrete | The fabricator/manufacturer designation for the sample | AM 492 |
| A detailed description of where the material sample was collected | Wheel Barrow from Chute | Where the material sample would have been placed if not sampled | CIDH Pile 1 and 3 and 5 |
| From Lot No. | Bag Lot No. |
Submitted Tests
| DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Date Added | Verified? | Release Date | Test Comments | Privacy Level | Actions |
|---|---|---|---|---|---|---|---|---|---|
| 2022-03-15-4-1 | CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders | Wesley Rider, CT D05 - Prunedale Field Laboratory | 04/11/2022 | 04/12/2022 | No | Test per current CTM 521 that refers to ASTM C39 |
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2022-03-15-4-1 CTM 521-June 2020