Sample Record
DIME Sample ID 2022-03-04-10
Project Information
| Project Identifiers | Project ID: 993236 DEA: 051K0504 EFIS: 0518000114 |
|---|---|
| DIST-CO-RTE-PM | 05-MON-1-55.7/55.9 |
| Award Date | 10/14/2021 |
| Closeout Date | 09/02/2022 |
| Work Description | CONSTRUCT EARTH RETAINING SYSTEM WITH CIDH PILE & STRUCTURAL CONCRETE. |
| Location Description | MONTEREY COUNTY NEAR LITTLE SUR RIVER FROM 0.4 MILE SOUTH OF LITTLE SUR RIVER BRIDGE TO 0.2 MILE SOUTH OF LITTLE SUR RIVER BRIDGE |
| QA Service Level | 1 (Verified on 10/06/2021) |
Owner Lab
- CT D05 - Prunedale Field Laboratory
Sample Information
| Sample Taken Date | 03/04/2022 | Sample Unique Key | 10 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 03/06/2022 | Sample type | Quality Assurance |
| A brief description of the sample | 3 - 4x8" Concrete Cylinders | The quantity of what the sample constitutes | 12 CY |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Wesley |
| Last name of sampler or witnessed by | Rider | Title of sampler | TET |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | 2022-03-04-9 | The fabricator/manufacturer/facility name | Las Animas, Marina CA |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | M779PR50S |
|---|---|---|---|
| The truck number from where the sample was collected | 115 | The batch plant ticket number from where the sample was collected | 200697 |
| Concrete batch plant | Las Animas Concrete | The fabricator/manufacturer designation for the sample | AM 493 |
| A detailed description of where the material sample was collected | Wheel Barrow from Chute | Where the material sample would have been placed if not sampled | CIDH Pile 14 |
| From Lot No. | Bag Lot No. |
Submitted Tests
| DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Date Added | Verified? | Release Date | Test Comments | Privacy Level | Actions |
|---|---|---|---|---|---|---|---|---|---|
| 2022-03-04-10-1 | CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders | F. Ortega, CT D05 - Prunedale Field Laboratory | 04/01/2022 | 04/04/2022 | No |
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2022-03-04-10-1 CTM 521-June 2020