Sample Record

DIME Sample ID 2014-11-17-3

Project Information

Project IdentifiersProject ID: 1095
DEA: 033797U4
EFIS: 0300020155
COOP: 030466
DIST-CO-RTE-PM03-SAC,SAC-80-R10.9/R11.7,M0.0/M10.4
Award Date07/29/2011
Closeout Date12/08/2017
Work DescriptionREPLACE PCCP, PLACE HMA, WIDEN BRIDGES AND CONSTRUCT SOUNDWALLS.
Location DescriptionYOLO AND SACRAMENTO COUNTIES IN AND NEAR WEST SACRAMENTO AND SACRAMENTO FROM ROUTE 80/84 SEPARATION TO WATT AVENUE OVERCROSSING
QA Service Level1 (Verified on 03/15/2012)

Owner Lab

  • CT HQ - Sacramento Concrete Testing Laboratory

Sample Information

Sample Taken Date11/17/2014 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing11/18/2014 Sample typeQuality Control
A brief description of the samplecylinders The quantity of what the sample constitutes6
From where was the sample collectedOther First name of sampler or witnessed bytoby
Last name of sampler or witnessed byphillips Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample ID0 The fabricator/manufacturer/facility namena
Transportation Laboratory (TL) Number150920 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifierUnknown Structure nameUnknown
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number1418831
The truck number from where the sample was collectedUnknown The batch plant ticket number from where the sample was collected00000000000000
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedfrom mix truck Where the material sample would have been placed if not sampledNot set
From Lot No.Not set Bag Lot No.Not set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2014-11-17-3-1ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensSV, CT HQ - Sacramento Concrete Testing Laboratory12/01/2014
Yes
12/01/2014Cylinders average diameters are not within 2% requirement Please check cylinder molds.Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2014-11-17-3-1 ASTM C39-10 (Verified)