Sample Record

DIME Sample ID 2022-01-24-3

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214579
DEA: 010B0904
EFIS: 0100020444
DIST-CO-RTE-PM01-DN-101-8.2/8.7
Award Date04/21/2020
Closeout Date12/02/2025
Work DescriptionPanther Creek & Hunter Creek Bridges
Location DescriptionDEL NORTE COUNTY NEAR KLAMATH AT PANTHER CREEK BRIDGE AND AT HUNTER CREEK BRIDGE
QA Service Level1 (Verified on 03/02/2020)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date01/24/2022 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing01/31/2022 Sample typeQuality Assurance
A brief description of the sampleLenton Couplers The quantity of what the sample constitutes120
From where was the sample collectedFabricator First name of sampler or witnessed byKevin
Last name of sampler or witnessed byCarpenter Title of samplerQA
Telephone number of sampler14156081742 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility namePJs Rebar
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormB24-007-22
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerDayton Intermediate Assembler or FabricatorPJ Rebar
Rebar Size#9 Coupler ModelDayton D101A
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)3500020968 Rebar Heat Number(s)350002096820
Rebar Size 2 9 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2022-01-24-3-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory02/02/202202/02/2022
Yes
02/04/2022Service SplicePublic - Test Data Visible
2022-01-24-3-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory02/02/202202/02/2022
Yes
02/04/2022Service SplicePublic - Test Data Visible
2022-01-24-3-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory02/02/202202/02/2022
Yes
02/04/2022Service SplicePublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2022-01-24-3-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2022-01-24-3-2 CTM 670-December 2013 (Verified)