Sample Record

DIME Sample ID 2014-10-13-4

Project Information

Project IdentifiersProject ID: 209175
DEA: 030F2204
EFIS: 0300000072
DIST-CO-RTE-PM03-ED-50-R30.7/R31.7
Award Date02/25/2014
Closeout Date07/30/2015
Work DescriptionREPLACE BRIDGE.
Location DescriptionSLY PARK UNDERCROSSING
QA Service Level1 (Verified on 11/01/2013)

Owner Lab

  • CT D03 - Sacramento Sanders Structures Construction Field Office

Sample Information

Sample Taken Date10/13/2014 Sample Unique Key4
Date that the sample was received by the laboratory/organization performing the testing10/14/2014 Sample typeVerification
A brief description of the sample6x12 concrete cylinders The quantity of what the sample constitutes2 6x12 concrete cylinders
From where was the sample collectedOther First name of sampler or witnessed byBrandon
Last name of sampler or witnessed byMiller Title of samplerStructure Representative
Telephone number of sampler(916) 505-6839 Laboratory sample identificationUnknown
Linked DIME Sample ID0 The fabricator/manufacturer/facility nameJobsite
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier25 0042 Structure nameSly Park Rd UC
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberSF850AFST0
The truck number from where the sample was collected18 The batch plant ticket number from where the sample was collected1051274
Concrete batch plant1B The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedDischarge from concrete truck into wheelbarrow Where the material sample would have been placed if not sampledNot set
From Lot No.Not set Bag Lot No.Not set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2014-10-13-4-1ASTM C1064-08: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement ConcreteBrandon Miller, CT D03 - Sacramento Sanders Structures Construction Field Office10/13/2014
Yes
10/20/2014Public - Test Data Visible
2014-10-13-4-2ASTM C143-10a: Standard Test Method for Slump of Hydraulic-Cement ConcreteBrandon Miller, CT D03 - Sacramento Sanders Structures Construction Field Office10/13/2014
Yes
10/20/2014Public - Test Data Visible
2014-10-13-4-3ASTM C231-10: Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure MethodBrandon Miller, CT D03 - Sacramento Sanders Structures Construction Field Office10/13/2014
Yes
10/20/2014Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2014-10-13-4-1 ASTM C1064-08 (Verified)
DIME Test ID: 2014-10-13-4-2 ASTM C143-10a (Verified)