Sample Record

DIME Sample ID 2022-01-08-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214671
DEA: 07303904
EFIS: 0714000044
DIST-CO-RTE-PM07-LA-10-31.2/37.2
Award Date11/25/2020
Closeout Date10/11/2023
Work DescriptionLANE REPLACEMENT
Location DescriptionLOS ANGELES COUNTY IN BALDWIN PARK AND WEST COVINA FROM 0.1 MILE EAST OF THE 10/605 SEPARATION TO 0.3 MILE WEST OF CITRUS STREET OVERCROSSING
QA Service Level1 (Verified on 01/21/2021)

Owner Lab

  • Kleinfelder, Incorporated - Los Angeles

Sample Information

Sample Taken Date01/08/2022 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing01/08/2022 Sample typePer Request
A brief description of the sampleA set of 2 LCB RS cylinders The quantity of what the sample constitutes130 CY
From where was the sample collectedJob Site First name of sampler or witnessed byMarcus
Last name of sampler or witnessed byMolina Title of samplerField Materials Tester
Telephone number of sampler9095343477 Laboratory sample identification220041
Linked DIME Sample ID The fabricator/manufacturer/facility nameSecurity Paving Burbank Batch Plant
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number04
The truck number from where the sample was collectedLoad 13 The batch plant ticket number from where the sample was collected1914
Concrete batch plantSecurity Paving Burbank Batch Plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedConcrete from wheelbarrow Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2022-01-08-1-1ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMarcus Molina, Kleinfelder, Incorporated - Los Angeles01/08/2022
Yes
01/09/2022Witnessed QC perform opening age breaks with an average of 1210 psi at 12 hours. Public - Test Data Visible
2022-01-08-1-2CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersEdmond Jabbour, Kleinfelder, Incorporated - Los Angeles01/15/2022
Yes
01/17/20227 day breaks for log # 220041.Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2022-01-08-1-1 ASTM C39-21 (Verified)
DIME Test ID: 2022-01-08-1-2 CTM 521-June 2020 (Verified)