Sample Record

DIME Sample ID 2021-09-17-49

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214686
DEA: 030H4004
EFIS: 0315000164
DIST-CO-RTE-PM03-NEV,PLA,YOL-80-VAR
Award Date04/15/2020
Closeout Date08/11/2023
Work DescriptionREPLACE ELECTRICAL SIGNS & INSTALL FIBER OPTIC COMMUNICATION LINES.
Location DescriptionNEVADA, PLACER AND YOLO COUNTIES AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 03/24/2020)

Owner Lab

  • RMA Group - Rancho Cordova

Sample Information

Sample Taken Date09/17/2021 Sample Unique Key49
Date that the sample was received by the laboratory/organization performing the testing09/17/2021 Sample typeQuality Control
A brief description of the sampleConcrete The quantity of what the sample constitutes100 cy
From where was the sample collectedJob Site First name of sampler or witnessed byMichael
Last name of sampler or witnessed byThomas Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameTNT Materials - Truckee
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number6691
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected353955
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedsign foundation on East bound I80 Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2021-09-17-49-1CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement ConcreteMichael Thomas, RMA Group - Rancho Cordova09/17/202104/13/2022
Yes
04/13/2022Public - Test Data Visible
2021-09-17-49-2ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement ConcreteMichael Thomas, RMA Group - Rancho Cordova09/17/202104/13/2022
Yes
04/13/2022Public - Test Data Visible
2021-09-17-49-3CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersTodd Strait, RMA Group - Rancho Cordova10/15/202104/13/2022
Yes
04/13/2022Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-09-17-49-1 CTM 557-June 2020 (Verified)
DIME Test ID: 2021-09-17-49-2 ASTM C143-20 (Verified)