Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2021-10-19-6
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 212252 DEA: 033F5604 EFIS: 0313000033 |
|---|---|
| DIST-CO-RTE-PM | 03-SUT,YUB-20-17.0/17.1,0.0/0.4 |
| Award Date | 02/11/2021 |
| Closeout Date | 01/25/2023 |
| Work Description | INSTALL CAST-IN-STEEL SHELL CONCRETE PILE. |
| Location Description | SUTTER AND YUBA COUNTIES IN YUBA CITY AND MARYSVILLE AT THE FEATHER RIVER BRIDGE AND OVERHEAD |
| QA Service Level | 1 (Verified on 04/27/2018) |
Sample Information
| Sample Taken Date | 10/19/2021 | Sample Unique Key | 6 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/21/2021 |
| Sample type | Quality Assurance | A brief description of the sample | #7 t-heads |
| The quantity of what the sample constitutes | 5 lots t-heads | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Greg | Last name of sampler or witnessed by | Thompson |
| Title of sampler | Associate Steel Inspector | Telephone number of sampler | 510-376-7155 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Conco Reinforcing Benicia | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B9-100-21 | Structure unique identifier | |
| Structure name | Feather River Bridge Pile Cap | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Rebar Heat Number(s) | 3500020386 157421 | Head Manufacturer Lot Number(s) | t01 t02 t07 t12 t17 |
| Rebar Size | #7 | Headed Bar Model Name | HRC 555 |
| Size of Head | Full Size - 9x | Head Connection Type | Forged |
| Head Shape | Circular | Rebar Manufacturer | Nucor Gerdau Cascade |
| Head Manufacturer | Conco | Head Fabricator | Conco Benicia |
| Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2021-10-19-6-1 ASTM A970-15e1 (Verified)
DIME Test ID: 2021-10-19-6-2 ASTM A970-15e1 (Verified)
DIME Test ID: 2021-10-19-6-3 ASTM A970-15e1 (Verified)
DIME Test ID: 2021-10-19-6-4 ASTM A970-15e1 (Verified)
DIME Test ID: 2021-10-19-6-5 ASTM A970-15e1 (Verified)
DIME Test ID: 2021-10-19-6-6 ASTM A970-15e1 (Verified)
DIME Test ID: 2021-10-19-6-7 ASTM A970-15e1 (Verified)
DIME Test ID: 2021-10-19-6-8 ASTM A970-15e1 (Verified)
DIME Test ID: 2021-10-19-6-9 ASTM A970-15e1 (Verified)
DIME Test ID: 2021-10-19-6-10 ASTM A970-15e1 (Verified)
DIME Test ID: 2021-10-19-6-11 ASTM A970-15e1 (Verified)
DIME Test ID: 2021-10-19-6-12 ASTM A970-15e1 (Verified)
DIME Test ID: 2021-10-19-6-13 ASTM A970-15e1 (Verified)
DIME Test ID: 2021-10-19-6-14 ASTM A970-15e1 (Verified)
DIME Test ID: 2021-10-19-6-15 ASTM A970-15e1 (Verified)
