Sample Record
Owner Lab
- CT D08 - Fontana Field Testing Laboratory
DIME Sample ID 2021-10-05-36
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 215188 DEA: 080F5434 EFIS: 0817000239 Permit Numbers: 0823NMC0369 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-I-15,SR-91-6.1-7.6 |
| Award Date | 03/11/2020 |
| Closeout Date | 06/05/2024 |
| Work Description | I-15 ELC: 15/91 Express Lanes Connector Project (ELC) |
| Location Description | Junction of I-15 and SR-91 in Corona, CA |
| QA Service Level | 1 (Verified on 09/16/2020) |
Sample Information
| Sample Taken Date | 10/05/2021 | Sample Unique Key | 36 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/06/2021 |
| Sample type | Department Acceptance | A brief description of the sample | Concrete beams |
| The quantity of what the sample constitutes | 4 Beams | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Nathan / Zachariah | Last name of sampler or witnessed by | Ogbasellasie/ Roush |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 2JA1, 2JA2, 2JB1, 2JB2 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Cemex, Fontana | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 1605762 |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | TTI | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | On Job Site at Concrete Truck | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2021-10-05-36-1 CTM 523-July 2012 (Verified)
DIME Test ID: 2021-10-05-36-2 CTM 523-July 2012 (Verified)
DIME Test ID: 2021-10-05-36-3 CTM 533-June 2010 (Verified)
DIME Test ID: 2021-10-05-36-4 CTM 504-June 2010 (Verified)
DIME Test ID: 2021-10-05-36-5 CTM 518-June 2010 (Verified)
DIME Test ID: 2021-10-05-36-6 CTM 523-July 2012 (Verified)
DIME Test ID: 2021-10-05-36-7 CTM 523-July 2012 (Verified)