Sample Record
Owner Lab
- Sequoia Consultants
DIME Sample ID 2021-08-24-55
Project Information
Project Identifiers | Project ID: 215236 DEA: 081C6804 EFIS: 0812000343 |
---|---|
DIST-CO-RTE-PM | 08-RIV-74,79and371-Varies |
Award Date | 12/29/2020 |
Closeout Date | Not set |
Work Description | REPLACE STRUCTURAL CONCRETE BRIDGE, RETAINING WALL AND BOX CULVERT. |
Location Description | RIVERSIDE COUNTY AT VARIOUS LOCATIONS |
QA Service Level | 1 (Verified on 03/02/2021) |
Sample Information
Sample Taken Date | 08/24/2021 | Sample Unique Key | 55 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/25/2021 |
Sample type | Quality Control | A brief description of the sample | 6x12 concrete cylinders |
The quantity of what the sample constitutes | 100CYDS | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Omar | Last name of sampler or witnessed by | Valdez |
Title of sampler | Field Technician | Telephone number of sampler | |
Laboratory sample identification | C082421-200 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Cemex Temecula | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | Arroyo Seco bridge |
Material Information
Material Type | Concrete | The concrete mix design number | 1610974 |
---|---|---|---|
The truck number from where the sample was collected | 10067270 | The batch plant ticket number from where the sample was collected | 29818241 |
Concrete batch plant | Cemex Temecula | The fabricator/manufacturer designation for the sample | Mix |
A detailed description of where the material sample was collected | Discharge chute from back of truck | Where the material sample would have been placed if not sampled | Abutment 1 and 2 footings |
From Lot No. | Bag Lot No. |
Submitted Tests
DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
---|---|---|---|---|---|---|---|---|
2021-08-24-55-1 | CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders | Ruben Jimenez, Sequoia Consultants | 09/21/2021 | Ken Mancebo | No | Info |
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2021-08-24-55-1 CTM 521-June 2020