Sample Record
Owner Lab
- CT HQ - QASI Bay Area Field Office
DIME Sample ID 2021-10-05-7
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 213411 DEA: 030H10U4 EFIS: 0317000246 |
|---|---|
| DIST-CO-RTE-PM | 03-SAC-5-9.7/24.9 |
| Award Date | 05/01/2019 |
| Closeout Date | 02/22/2024 |
| Work Description | Not set |
| Location Description | Construction on state highway in Sacramento County in and near Sacramento from 1.1 miles south of Elk Grove Boulevard to American River Viaduct |
| QA Service Level | 1 (Verified on 07/19/2019) |
Sample Information
| Sample Taken Date | 10/05/2021 | Sample Unique Key | 7 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/20/2021 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4" F1554 Gr. 55 All thread rod |
| The quantity of what the sample constitutes | 800 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Lund |
| Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | 3854470624 |
| Laboratory sample identification | na | Linked DIME Sample ID | na |
| The fabricator/manufacturer/facility name | Universal Industrial Sales, Inc | Transportation Laboratory (TL) Number | na |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B390-176-21 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | na |
|---|---|---|---|
| Heat Number(s) | 120203163961 | Nut Mfg. Lot Number(s) | na |
| Washer Mfg. Lot Number(s) | na | Bolt Specification | F1554 gr 55 |
| Bolt Length(s) | 10 1/2" | Nut Specification | na |
| Washer Specification | na | Finish | HDG |
| Diameter/Size | 3/4" | Bolt Mfg. Lot Number | na |
| Rocap Test Requirement(s) | na | Lubricant Requirements(s) | na |
| Washer Inner Diameter(s) |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2021-10-05-7-1 ASTM A370-15 (Verified)
DIME Test ID: 2021-10-05-7-2 ASTM A370-15 (Verified)
DIME Test ID: 2021-10-05-7-3 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-10-05-7-4 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-10-05-7-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-10-05-7-6 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-10-05-7-7 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-10-05-7-8 ASTM B499-14 (Verified)
DIME Test ID: 2021-10-05-7-9 ASTM B499-14 (Verified)
DIME Test ID: 2021-10-05-7-10 ASTM B499-14 (Verified)
DIME Test ID: 2021-10-05-7-11 ASTM B499-14 (Verified)
DIME Test ID: 2021-10-05-7-12 ASTM B499-14 (Verified)