Sample Record

DIME Sample ID 2021-08-31-50

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214814
DEA: 100Y6004
EFIS: 1013000244
DIST-CO-RTE-PM10-MPA-140-21.2/21.8
Award Date03/02/2021
Closeout Date05/11/2023
Work DescriptionINSTALL WARNING LIGHT & LIGHTING SYSTEMS & PLACE MINOR CONCRETE.
Location DescriptionMARIPOSA COUNTY AT MARIPOSA FROM SOUTH JUNCTION 49 TO 12TH STREET
QA Service Level1 (Verified on 03/30/2020)

Owner Lab

  • RMA Group - Rancho Cordova

Sample Information

Sample Taken Date08/31/2021 Sample Unique Key50
Date that the sample was received by the laboratory/organization performing the testing08/31/2021 Sample typeQuality Control
A brief description of the sampleConcrete The quantity of what the sample constitutes100 cy
From where was the sample collectedSupplier First name of sampler or witnessed byAndrew
Last name of sampler or witnessed byClarke Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameOutback Materials
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number72T1C02
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected27387
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedRetaining wall number 1, 3, and 4 Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2021-08-31-50-1CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement ConcreteAndrew Clarke, RMA Group - Rancho Cordova08/31/202104/13/2022
Yes
04/13/2022Public - Test Data Visible
2021-08-31-50-2CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure MethodAndrew Clarke, RMA Group - Rancho Cordova08/31/202104/13/2022
Yes
04/13/2022Public - Test Data Visible
2021-08-31-50-3CTM 518-June 2010: Method of Test for Unit Weight of Fresh ConcreteAndrew Clarke, RMA Group - Rancho Cordova08/31/202104/13/2022
Yes
04/13/2022Public - Test Data Visible
2021-08-31-50-4ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement ConcreteAndrew Clarke, RMA Group - Rancho Cordova08/31/202104/13/2022
Yes
04/13/2022Public - Test Data Visible
2021-08-31-50-5CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersTodd Strait, RMA Group - Rancho Cordova09/28/202104/13/2022
Yes
04/13/2022Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-08-31-50-1 CTM 557-June 2020 (Verified)
DIME Test ID: 2021-08-31-50-2 CTM 504-June 2010 (Verified)
DIME Test ID: 2021-08-31-50-3 CTM 518-June 2010 (Verified)
DIME Test ID: 2021-08-31-50-4 ASTM C143-20 (Verified)
DIME Test ID: 2021-08-31-50-5 CTM 521-June 2020 (Verified)