Sample Record
Owner Lab
- Kie-Con, Incorporated - Antioch
DIME Sample ID 2021-08-06-34
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 214663 DEA: 081F7304 EFIS: 0815000034 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-215-2.7 |
| Award Date | 03/04/2021 |
| Closeout Date | 06/03/2025 |
| Work Description | REPLACE CONCRETE BRIDGE, PLACE CONCRETE PCPS GIRDERS AND HMA. |
| Location Description | SAN BERNARDINO COUNTY IN COLTON AT WASHINGTON STREET OVERCROSSING |
| QA Service Level | 1 (Verified on 02/24/2021) |
Sample Information
| Sample Taken Date | 08/06/2021 | Sample Unique Key | 34 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/07/2021 |
| Sample type | Quality Control | A brief description of the sample | 6 x 12 Concrete Cylinders |
| The quantity of what the sample constitutes | 4 cy | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Stephen | Last name of sampler or witnessed by | Haynes |
| Title of sampler | QC Inspector Technician | Telephone number of sampler | 9253317125 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | KIE-CON, INC | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | CTP70-V81 |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 111547 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | L5N 8/6/2021 | |
| A detailed description of where the material sample was collected | Concrete sample from wheelbarrow | Where the material sample would have been placed if not sampled | Piling |
| From Lot No. | Bag Lot No. |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2021-08-06-34-1 ASTM C39-18 (Verified)
DIME Test ID: 2021-08-06-34-2 ASTM C39-18 (Verified)
DIME Test ID: 2021-08-06-34-3 ASTM C39-18 (Verified)
DIME Test ID: 2021-08-06-34-4 ASTM C39-18 (Verified)
DIME Test ID: 2021-08-06-34-5 ASTM C1064-17 (Verified)
DIME Test ID: 2021-08-06-34-6 ASTM C143-20 (Verified)
DIME Test ID: 2021-08-06-34-7 ASTM C138-17a (Verified)