Sample Record

DIME Sample ID 2021-08-31-10

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 215396
DEA: 042K8404
EFIS: 0417000031
DIST-CO-RTE-PM04-SOL-29,80-0.0,0.8/1.6
Award Date03/26/2021
Closeout Date02/16/2024
Work DescriptionHMA, STRUCTURAL CONCRETE, CIDH PILING AND REBAR.
Location DescriptionSOLANO COUNTY IN VALLEJO AT ROUTE 80/29 SEPARATION AND ON ROUTE 80 FROM 0.2 MILE NORTH OF CARQUINEZ BRIDGE TOLL PLAZA TO 0.3 MILE SOUTH OF MAGAZINE STREET OVERCROSSING
QA Service Level1 (Verified on 01/25/2021)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date08/31/2021 Sample Unique Key10
Date that the sample was received by the laboratory/organization performing the testing09/03/2021 Sample typeQuality Assurance
A brief description of the sample#8 A2 Lenton form-savers The quantity of what the sample constitutes8
From where was the sample collectedFabricator First name of sampler or witnessed byKevin
Last name of sampler or witnessed byCarpenter Title of samplerQA
Telephone number of sampler14156081742 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameReinforcing
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormB24-072-21
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerGerdau
Coupler ManufacturerEaton Intermediate Assembler or Fabricator
Rebar Size#8 Coupler ModelA2 Lenton Couplers
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)190370 Rebar Heat Number(s)58048123
Rebar Size 2 8 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2021-08-31-10-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory09/02/202109/02/2021
Yes
09/07/2021Service SplicePublic - Test Data Visible
2021-08-31-10-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory09/02/202109/02/2021
Yes
09/07/2021Service SplicePublic - Test Data Visible
2021-08-31-10-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory09/02/202109/02/2021
Yes
09/07/2021Service SplicePublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-08-31-10-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-08-31-10-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-08-31-10-3 CTM 670-December 2013 (Verified)