Sample Record

DIME Sample ID 2021-08-20-6

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214640
DEA: 042J7204
EFIS: 0415000016
DIST-CO-RTE-PM04-CC-580-1.17
Award Date02/25/2021
Closeout Date12/01/2023
Work DescriptionSTEGE DRAIN SUPER-STRUCTURE, PRECAST VOIDED SLABS
Location DescriptionCONTRA COSTA COUNTY IN RICHMOND FROM 0.3 MILE EAST OF STEGE DRAIN BRIDGE TO 0.3 MILE WEST OF BAYVIEW AVENUE OVERCROSSING
QA Service Level1 (Verified on 01/27/2020)

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

Sample Information

Sample Taken Date08/20/2021 Sample Unique Key6
Date that the sample was received by the laboratory/organization performing the testing08/27/2021 Sample typeVerification
A brief description of the sample#11 ASTM A706 HRC 120 T Heads Lot 1 The quantity of what the sample constitutes4
From where was the sample collectedFabricator First name of sampler or witnessed byArthur
Last name of sampler or witnessed byPeterson Title of samplerQA Specialist
Telephone number of sampler7073428602 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameHRC Fountain Valley
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL110-122-21
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)4108404 Head Manufacturer Lot Number(s)10020862722
Rebar Size#11 Headed Bar Model NameHRC 120 T Heads
Size of HeadFull Size - 9x Head Connection TypeFriction Weld
Head ShapeSquare Rebar ManufacturerCMC Steel Arizona
Head ManufacturerNucor Head FabricatorHRC Fountain Valley
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2021-08-20-6-1ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory08/31/202108/31/2021
Yes
09/01/2021Ok NeckingPublic - Test Data Visible
2021-08-20-6-2ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory08/31/202108/31/2021
Yes
09/01/2021Ok NeckingPublic - Test Data Visible
2021-08-20-6-3ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory08/31/202108/31/2021
Yes
09/01/2021Ok NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-08-20-6-1 ASTM A970-15e1 (Verified)
DIME Test ID: 2021-08-20-6-2 ASTM A970-15e1 (Verified)
DIME Test ID: 2021-08-20-6-3 ASTM A970-15e1 (Verified)