Sample Record

DIME Sample ID 2021-08-20-2

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 215129
DEA: 050N73U4
EFIS: 0520000166
DIST-CO-RTE-PM05-SB-101-7.3/9.6
Award Date10/22/2020
Closeout Date12/11/2023
Work Description!!Please CC Office Engineer Gabrielle Herrera on reports to RE and SR!! Segment 4C - Summerland: Construct HOV lanes and rehabilitation. Source inspection of sign structure trusses, lighting structures, steel soldier piles, epoxy coated rebar,
Location DescriptionSUMMERLAND FROM 0.2 MILES NORTH OF PARDARO LANE OVERCROSSING TO SAN YSIDRO CREEK BRIDGE
QA Service Level1 (Verified on 08/24/2020)

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

Sample Information

Sample Taken Date08/20/2021 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing08/25/2021 Sample typeQuality Assurance
A brief description of the sampleASTM A706 GR 60 Hoop The quantity of what the sample constitutes4 Ea.
From where was the sample collectedSource First name of sampler or witnessed byNick
Last name of sampler or witnessed byHoffmann Title of samplerQA Inspector
Telephone number of sampler510-542-9827 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCMC Etiwanda
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL124-56-21
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4110381
Hoop Manufacturer Lot Number(s)18, 23 Material Standard CodeASTM A706
Material Grade60 Rebar Size#6
Diameter of Hoop2'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Rebar
Welding CompanyCMC Etiwanda Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2021-08-20-2-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory08/26/202108/26/2021
Yes
08/26/2021Ok NeckingPublic - Test Data Visible
2021-08-20-2-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory08/26/202108/26/2021
Yes
08/26/2021Ok NeckingPublic - Test Data Visible
2021-08-20-2-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory08/26/202108/26/2021
Yes
08/26/2021Ok NeckingPublic - Test Data Visible
2021-08-20-2-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory08/26/202108/26/2021
Yes
08/26/2021Ok NeckingPublic - Test Data Visible
2021-08-20-2-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory08/26/202108/26/2021
Yes
08/26/2021Ok NeckingPublic - Test Data Visible
2021-08-20-2-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory08/26/202108/26/2021
Yes
08/26/2021Ok NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-08-20-2-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-08-20-2-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-08-20-2-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-08-20-2-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-08-20-2-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-08-20-2-6 CTM 670-December 2013 (Verified)