Sample Record

Owner Lab

  • CT - Unassigned/General Field Laboratory

DIME Sample ID 2021-08-03-5

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214469
DEA: 030H08U4
EFIS: 0319000029
DIST-CO-RTE-PM03-SAC-50-L0.2/R6.1
Award Date06/30/2020
Closeout DateNot set
Work DescriptionSac 50 Design Build PLEASE NOTE THAT DESIGN BUILDER MUST PERFORM QUALITY VALIDATION TESTING IN ACCORDANCE WITH THE MATERIAL CONTROL SCHEDULE (MCS) FOR ITEMS SUCH AS STRANDS, HS BOLTS, ELASTOMERIC BEARING PADS, JOINT SEALANTS, COUPLERS & WELDED HOOPS, ETC
Location DescriptionFROM 0.1 MILE EAST OF I-5 TO 0.8 MILE EAST OF WATT AVE
QA Service Level1 (Verified on 10/23/2019)

Sample Information

Sample Taken Date08/03/2021 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/09/2021
Sample typeQuality Assurance A brief description of the sampleA706 Grade 60 Rebar
The quantity of what the sample constitutes950 pcs From where was the sample collectedSource
First name of sampler or witnessed byWilliam Last name of sampler or witnessed byClifford
Title of samplerQA Inspector Telephone number of sampler7142674733
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameMartinez steel Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL78-057-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)145421
Hoop Manufacturer Lot Number(s)1,2 Material Standard CodeASTM A706
Material Grade60 Rebar Size#8
Diameter of Hoop3'-8" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCascade
Welding CompanyMartinez Steel Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-08-03-5-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/10/2021fsaylor
Yes
08/10/2021OK Necking
2021-08-03-5-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/10/2021fsaylor
Yes
08/10/2021OK Necking
2021-08-03-5-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/10/2021fsaylor
Yes
08/10/2021OK Necking
2021-08-03-5-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/10/2021fsaylor
Yes
08/10/2021OK Necking
2021-08-03-5-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/10/2021fsaylor
Yes
08/10/2021OK Necking
2021-08-03-5-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/10/2021fsaylor
Yes
08/10/2021OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-08-03-5-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-08-03-5-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-08-03-5-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-08-03-5-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-08-03-5-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-08-03-5-6 CTM 670-December 2013 (Verified)