Sample Record
DIME Sample ID 2021-07-08-6
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 214922 DEA: 100X3104 EFIS: 1013000265 |
|---|---|
| DIST-CO-RTE-PM | 10-SJ-99-16.8/17.6 |
| Award Date | 06/30/2020 |
| Closeout Date | 04/07/2022 |
| Work Description | REPLACE BRIDGE. |
| Location Description | SAN JOAQUIN COUNTY IN STOCKTON FROM 0.4 MILE SOUTH TO 0.4 MILE NORTH OF FARMINGTON ROAD OVERCROSSING |
| QA Service Level | 1 (Verified on 04/28/2020) |
Owner Lab
- CT HQ - QASI Bay Area Field Office
Sample Information
| Sample Taken Date | 07/08/2021 | Sample Unique Key | 6 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/08/2021 | Sample type | Quality Assurance |
| A brief description of the sample | All Thread Rod | The quantity of what the sample constitutes | 380 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | David |
| Last name of sampler or witnessed by | Lund | Title of sampler | CT METS QA INSPECTOR |
| Telephone number of sampler | 385-447-0624 | Laboratory sample identification | na |
| Linked DIME Sample ID | na | The fabricator/manufacturer/facility name | Universal Industrial Sales Inc |
| Transportation Laboratory (TL) Number | na | Inspector Lot Number from the Transportation Laboratory (TL) Form | B390-090-21 |
| Structure unique identifier | Structure name | na | |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | na |
|---|---|---|---|
| Heat Number(s) | 10656870 | Nut Mfg. Lot Number(s) | na |
| Washer Mfg. Lot Number(s) | na | Bolt Specification | A449 |
| Bolt Length(s) | 8" | Nut Specification | na |
| Washer Specification | na | Finish | HGD |
| Diameter/Size | 5/8" | Bolt Mfg. Lot Number | 33988 |
| Rocap Test Requirement(s) | na | Lubricant Requirements(s) | na |
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2021-07-08-6-1 ASTM F606-14 (Verified)
DIME Test ID: 2021-07-08-6-2 ASTM F606-14 (Verified)
DIME Test ID: 2021-07-08-6-3 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-07-08-6-4 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-07-08-6-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-07-08-6-6 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-07-08-6-7 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-07-08-6-8 ASTM B499-14 (Verified)
DIME Test ID: 2021-07-08-6-9 ASTM B499-14 (Verified)
DIME Test ID: 2021-07-08-6-10 ASTM B499-14 (Verified)
DIME Test ID: 2021-07-08-6-11 ASTM B499-14 (Verified)
DIME Test ID: 2021-07-08-6-12 ASTM B499-14 (Verified)