Sample Record

DIME Sample ID 2021-07-01-14

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 215424
DEA: 024G4404
EFIS: 0214000013
DIST-CO-RTE-PM02-SIS-3-38.0/38.6
Award Date04/05/2021
Closeout Date08/14/2023
Work DescriptionBRIDGE REPLACEMENT
Location DescriptionSISKIYOU COUNTY ABOUT 6 MILES NORTH OF FORT JONES FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF LOWER MOFFETT CREEK ROAD
QA Service Level1 (Verified on 01/19/2021)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date07/01/2021 Sample Unique Key14
Date that the sample was received by the laboratory/organization performing the testing07/06/2021 Sample typeQuality Assurance
A brief description of the sampleGreen Epoxy Rebar The quantity of what the sample constitutes2
From where was the sample collectedJob Site First name of sampler or witnessed byJane
Last name of sampler or witnessed byLillard Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameNucor Erico Lention
Transportation Laboratory (TL) NumberC926651 Inspector Lot Number from the Transportation Laboratory (TL) FormS5202721
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM7 - Epoxy Coated Rebar Rebar Heat Number(s)3600019380
Rebar Epoxy Batch Number(s)3CH2101005 Rebar Coating SpecificationASTM A775
Rebar Size (#)5 Rebar Coating ColorGreen
Rebar ManufacturerNucor Rebar CoaterFCS Construction
Rebar Powder Manufacturer3M Release Number
Quality Assurance Code

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2021-07-01-14-1ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory07/06/2021
Yes
07/07/2021Public - Test Data Visible
2021-07-01-14-2ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory07/06/2021
Yes
07/07/2021Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-07-01-14-1 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2021-07-01-14-2 ASTM A775-07b-re14 (Verified)