Sample Record

DIME Sample ID 2021-06-29-14

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 213337
DEA: 024F5404
EFIS: 0213000004
DIST-CO-RTE-PM02-SIS-5-R15.3/R16.5
Award Date07/30/2018
Closeout Date05/23/2022
Work DescriptionBRIDGE REPLACEMENT - SOUTHBOUND ONLY
Location DescriptionSISKIYOU COUNTY NEAR WEED FROM 0.1 MILE SOUTH OF DEETZ ROAD UNDERCROSSING TO 0.6 MILE NORTH OF BLACK BUTTE OVERHEAD 02-0004L
QA Service Level1 (Verified on 11/14/2018)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date06/29/2021 Sample Unique Key14
Date that the sample was received by the laboratory/organization performing the testing06/30/2021 Sample typeQuality Assurance
A brief description of the sample#11 Lenton couplers The quantity of what the sample constitutes150 Couplers
From where was the sample collectedJob Site First name of sampler or witnessed byAndy
Last name of sampler or witnessed byOSullivan Title of samplerSR
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility namePSG
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerLenton Intermediate Assembler or Fabricator
Rebar Size#11 Coupler ModelLenton STD A2
Coating StandardsASTM A775 epoxy Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)L9289 Rebar Heat Number(s)1201027613
Rebar Size 2 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2021-06-29-14-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory06/30/202106/30/2021
Yes
06/30/2021Service SplicePublic - Test Data Visible
2021-06-29-14-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory06/30/202106/30/2021
Yes
06/30/2021Service SplicePublic - Test Data Visible
2021-06-29-14-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory06/30/202106/30/2021
Yes
06/30/2021Service SplicePublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-06-29-14-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-06-29-14-2 CTM 670-December 2013 (Verified)