Sample Record

Owner Lab

  • CT HQ - Sacramento Concrete Testing Laboratory

DIME Sample ID 2021-06-02-2

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214899
DEA: 033H4504
EFIS: 0318000001
DIST-CO-RTE-PM03-ED-50-33.8/34.2
Award Date07/29/2020
Closeout DateNot set
Work DescriptionCONSTRUCT RW, WIDEN RDWY, COLD PLANE AC PVMT, & HMA OVERLAY.
Location DescriptionEL DORADO COUNTY AT FRESH POND FROM 0.6 TO 0.2 MILE WEST OF FOREST ROAD/OUTER LIMITS LANE
QA Service Level1 (Verified on 04/15/2020)

Sample Information

Sample Taken Date06/02/2021 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/03/2021
Sample typeQuality Assurance A brief description of the sampleGrout Cubes
The quantity of what the sample constitutes12 Cubes From where was the sample collectedJob Site
First name of sampler or witnessed byDave Last name of sampler or witnessed byCarlin
Title of samplerSR Telephone number of sampler916-801-9674
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility namePacific Coast Drilling Company Transportation Laboratory (TL) Number79401
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameSoldier Pile Wall

Material Information

Material TypeCementitious BrandBasalite
MillLehigh Type of Cementitious MaterialType II Cement

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-06-02-2-1ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)Spencer Adams, CT HQ - Sacramento Concrete Testing Laboratory06/04/2021
Yes
06/05/20212 Day
2021-06-02-2-2ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)Spencer Adams, CT HQ - Sacramento Concrete Testing Laboratory06/05/2021Spencer Adams
Yes
06/05/2021Specimen 3 was eliminated from the average for being outside allowable limits per Section 12 of ASTM C109
2021-06-02-2-3ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)Spencer Adams, CT HQ - Sacramento Concrete Testing Laboratory06/06/2021Spencer Adams
Yes
06/06/2021Specimen 2 was eliminated from the average for being outside allowable limits per Section 12 of ASTM C109
2021-06-02-2-4ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)Spencer Adams, CT HQ - Sacramento Concrete Testing Laboratory06/09/2021
Yes
06/09/20217 Day; Specimen 2 excluded for being out of range of other two specimens per ASTM C109-20.

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-06-02-2-1 ASTM C109-16a (Verified)
DIME Test ID: 2021-06-02-2-2 ASTM C109-16a (Verified)
DIME Test ID: 2021-06-02-2-3 ASTM C109-16a (Verified)
DIME Test ID: 2021-06-02-2-4 ASTM C109-16a (Verified)