Sample Record
DIME Sample ID 2021-05-27-2
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 212252 DEA: 033F5604 EFIS: 0313000033 |
|---|---|
| DIST-CO-RTE-PM | 03-SUT,YUB-20-17.0/17.1,0.0/0.4 |
| Award Date | 02/11/2021 |
| Closeout Date | 01/25/2023 |
| Work Description | INSTALL CAST-IN-STEEL SHELL CONCRETE PILE. |
| Location Description | SUTTER AND YUBA COUNTIES IN YUBA CITY AND MARYSVILLE AT THE FEATHER RIVER BRIDGE AND OVERHEAD |
| QA Service Level | 1 (Verified on 04/27/2018) |
Owner Lab
- CT HQ - QASI Los Angeles Field Office
Sample Information
| Sample Taken Date | 05/27/2021 | Sample Unique Key | 2 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 05/31/2021 | Sample type | Quality Assurance |
| A brief description of the sample | Flash Welded Rebar Hoops | The quantity of what the sample constitutes | 3220 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Steve |
| Last name of sampler or witnessed by | Hall | Title of sampler | CT METS QA INSPECTOR |
| Telephone number of sampler | 6466327821 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | TNT Rebar | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | L134-088-21 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 3500015581 |
| Hoop Manufacturer Lot Number(s) | 1, 6, 11, 16, 21 and 22 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | #6 |
| Diameter of Hoop | 3'-2" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Nucor Seattle |
| Welding Company | TNT Rebar | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2021-05-27-2-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-05-27-2-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-05-27-2-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-05-27-2-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-05-27-2-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-05-27-2-6 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-05-27-2-7 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-05-27-2-8 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-05-27-2-9 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-05-27-2-10 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-05-27-2-11 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-05-27-2-12 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-05-27-2-13 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-05-27-2-14 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-05-27-2-15 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-05-27-2-16 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-05-27-2-17 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-05-27-2-18 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-05-27-2-19 CTM 670-December 2013 (Verified)