Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2021-03-23-2

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214702
DEA: 030F2864
EFIS: 0320000123
DIST-CO-RTE-PM03-SAC-99-7.92 / 8.4
Award Date06/24/2020
Closeout Date11/28/2023
Work DescriptionRemove and replace Consumnes River and Consumnes River Overflow bridge
Location DescriptionSacramento County
QA Service Level1 (Verified on 04/20/2020)

Sample Information

Sample Taken Date03/23/2021 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing03/26/2021 Sample typeQuality Assurance
A brief description of the sample6'-2" diameter welded hoops The quantity of what the sample constitutes885
From where was the sample collectedManufacturer First name of sampler or witnessed byAndrew
Last name of sampler or witnessed byWebster Title of samplerQA Inspector
Telephone number of sampler(925) 418-9838 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCMC Rebar-Etiwanda
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormB201-018-21
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4104477
Hoop Manufacturer Lot Number(s)35 38 Material Standard CodeASTM A706
Material Grade60 Rebar Size#8
Diameter of Hoop6'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Steel Arizona
Welding CompanyCMC Rebar (Etiwanda) Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2021-03-23-2-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory03/30/202103/30/2021
Yes
03/30/2021OK NeckingPublic - Test Data Visible
2021-03-23-2-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory03/30/202103/30/2021
Yes
03/30/2021OK NeckingPublic - Test Data Visible
2021-03-23-2-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory03/30/202103/30/2021
Yes
03/30/2021OK NeckingPublic - Test Data Visible
2021-03-23-2-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory03/30/202103/30/2021
Yes
03/30/2021OK NeckingPublic - Test Data Visible
2021-03-23-2-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory03/30/202103/30/2021
Yes
03/30/2021OK NeckingPublic - Test Data Visible
2021-03-23-2-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory03/30/202103/30/2021
Yes
03/30/2021OK NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-03-23-2-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-03-23-2-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-03-23-2-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-03-23-2-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-03-23-2-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-03-23-2-6 CTM 670-December 2013 (Verified)