Sample Record

DIME Sample ID 2021-03-12-3

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214579
DEA: 010B0904
EFIS: 0100020444
DIST-CO-RTE-PM01-DN-101-8.2/8.7
Award Date04/21/2020
Closeout Date12/02/2025
Work DescriptionPanther Creek & Hunter Creek Bridges
Location DescriptionDEL NORTE COUNTY NEAR KLAMATH AT PANTHER CREEK BRIDGE AND AT HUNTER CREEK BRIDGE
QA Service Level1 (Verified on 03/02/2020)

Owner Lab

  • CT HQ - QASI Bay Area Field Office

Sample Information

Sample Taken Date03/12/2021 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing03/16/2021 Sample typeQuality Assurance
A brief description of the sampleHRC 500 510 Couplers The quantity of what the sample constitutes24 ea
From where was the sample collectedFabricator First name of sampler or witnessed byRyan
Last name of sampler or witnessed byParr Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility namePJs Rebar
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormB373-025-21
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC
Coupler ManufacturerHRC Intermediate Assembler or Fabricator
Rebar Size#8 Coupler ModelHRC 500/510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)A194563, A196207 Rebar Heat Number(s)4104475
Rebar Size 2 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2021-03-12-3-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory03/16/202103/16/2021
Yes
03/16/2021OK NeckingPublic - Test Data Visible
2021-03-12-3-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory03/16/202103/16/2021
Yes
03/16/2021OK NeckingPublic - Test Data Visible
2021-03-12-3-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory03/16/202103/16/2021
Yes
03/16/2021OK NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-03-12-3-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-03-12-3-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-03-12-3-3 CTM 670-December 2013 (Verified)