Sample Record

DIME Sample ID 2021-03-01-2

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 215075
DEA: 060Q9104
EFIS: 0614000005
DIST-CO-RTE-PM06-TUL-99-19.2/19.8
Award Date09/25/2020
Closeout Date05/11/2023
Work DescriptionBRIDGE DECK AND OUTSIDE GIRDER REPLACEMENT.
Location DescriptionTULARE COUNTY NEAR TIPTON FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF AVENUE 152 OVERCROSSING
QA Service Level1 (Verified on 07/28/2020)

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

Sample Information

Sample Taken Date03/01/2021 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing03/04/2021 Sample typeQuality Assurance
A brief description of the sampleASTM A706 Grade 60 Welded Hoops The quantity of what the sample constitutes4
From where was the sample collectedFabricator First name of sampler or witnessed byArthur
Last name of sampler or witnessed byPeterson Title of sampler
Telephone number of sampler7073428602 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameTNT Rebar
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL110-023-21
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)1202028162
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size#6
Diameter of Hoop3'-8" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2021-03-01-2-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory03/05/202103/05/2021
Yes
03/08/2021Ok NeckingPublic - Test Data Visible
2021-03-01-2-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory03/05/202103/05/2021
Yes
03/08/2021Ok NeckingPublic - Test Data Visible
2021-03-01-2-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory03/05/202103/05/2021
Yes
03/08/2021Ok NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-03-01-2-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-03-01-2-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-03-01-2-3 CTM 670-December 2013 (Verified)