Sample Record
Owner Lab
- Granite Construction Company - Coastal
DIME Sample ID 2020-01-17-19
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 01/17/2020 | Sample Unique Key | 19 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 01/17/2020 | Sample type | Quality Control |
| A brief description of the sample | agg for rock quality | The quantity of what the sample constitutes | Multiple bags blended agg |
| From where was the sample collected | Source | First name of sampler or witnessed by | Daniel |
| Last name of sampler or witnessed by | Miltz | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Salinas Asphalt Facility | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-27-0028::HANDLEY RANCH QUARRY |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Sample taken from hot bins | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | Not set |
JMF Information
| HMA Design ID | JMF3512-2021-32-20_1580 | Date Created | 02/07/2021 |
|---|---|---|---|
| Submittal | JMF3511-362-2021-35 Submittal In Progress JMF3511-362-2021-36 Submittal Completeness in Review |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2020-01-17-19-1 AASHTO T335-09r13 (Verified)
DIME Test ID: 2020-01-17-19-2 AASHTO T335-09r13 (Verified)
DIME Test ID: 2020-01-17-19-3 AASHTO T335-09r13 (Verified)
DIME Test ID: 2020-01-17-19-4 AASHTO T96-02r10 (Verified)
DIME Test ID: 2020-01-17-19-5 AASHTO T176-08 (Verified)
DIME Test ID: 2020-01-17-19-6 AASHTO T304-11 (Verified)
DIME Test ID: 2020-01-17-19-7 AASHTO T85-13 (Verified)
DIME Test ID: 2020-01-17-19-8 AASHTO T84-14 (Verified)
DIME Test ID: 2020-01-17-19-9 ASTM D4791-10 (Verified)
DIME Test ID: 2020-01-17-19-10 CTM 204-June 2010 (Verified)