Sample Record

DIME Sample ID 2014-02-25-9506154

Project Information

Project IdentifiersProject ID: 7780
DEA: 112T1824
EFIS: 1100020051
DIST-CO-RTE-PM11-SD-805-4.7/5.6
Award Date01/03/2013
Closeout Date09/07/2018
Work DescriptionREPLACE STRUCTURE AND CONSTRUCT DIRECT ACCESS RAMP (DAR).
Location DescriptionSAN DIEGO COUNTY IN CHULA VISTA FROM 0.4 MILE SOUTH OF EAST PALOMAR STREET OVERCROSSING TO 0.1 MILE NORTH OF NAPLES STREET UNDERCROSSING
QA Service Level1 (Verified on 12/10/2012)

Owner Lab

  • RMA Group - Rancho Cucamonga

Sample Information

Sample Taken Date02/25/2014 Sample Unique Key9506154
Date that the sample was received by the laboratory/organization performing the testingNot set Sample typeQuality Control
A brief description of the sample6x12 concrete cylinders The quantity of what the sample constitutes5 Cylinders
From where was the sample collectedOther First name of sampler or witnessed bySean
Last name of sampler or witnessed byAnderson Title of samplerNot set
Telephone number of sampler(619) 647-4509 Laboratory sample identification2014-02-25-0950
Linked DIME Sample IDNot set The fabricator/manufacturer/facility nameVulcan Materials - Truck 852
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number103612F
The truck number from where the sample was collected852 The batch plant ticket number from where the sample was collected104510
Concrete batch plantMission Valley The fabricator/manufacturer designation for the sampleVulcan Materials Company
A detailed description of where the material sample was collectedRW 316R Footing Where the material sample would have been placed if not sampledNot set
From Lot No.Not set Bag Lot No.Not set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2014-02-25-9506154-1ASTM C143-10a: Standard Test Method for Slump of Hydraulic-Cement ConcreteSean Anderson, RMA Group - Rancho Cucamonga02/25/2014
Yes
03/14/2014Public - Test Data Visible
2014-02-25-9506154-2ASTM C1064-08: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement ConcreteSean Anderson, RMA Group - Rancho Cucamonga02/25/2014
Yes
03/14/2014Public - Test Data Visible
2014-02-25-9506154-3ASTM C231-10: Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure MethodSean Anderson, RMA Group - Rancho Cucamonga02/25/2014
Yes
03/14/2014Public - Test Data Visible
2014-02-25-9506154-4ASTM C138-10b: Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of ConcreteSean Anderson, RMA Group - Rancho Cucamonga02/25/2014
Yes
03/14/2014Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2014-02-25-9506154-1 ASTM C143-10a (Verified)
DIME Test ID: 2014-02-25-9506154-2 ASTM C1064-08 (Verified)
DIME Test ID: 2014-02-25-9506154-3 ASTM C231-10 (Verified)
DIME Test ID: 2014-02-25-9506154-4 ASTM C138-10b (Verified)