Sample Record

DIME Sample ID 2020-12-23-2

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 213469
DEA: 024C40V4
EFIS: 0218000125
DIST-CO-RTE-PM02-SHA-5-R3.8/R11.7
Award Date11/06/2018
Closeout Date08/16/2023
Work DescriptionWIDEN TO 6 LANES, BRIDGE REPLACEMENT AND WIDENING AND ROADWAY REHAB
Location DescriptionSHASTA COUNTY IN AND NEAR ANDERSON FROM ROUTE 5/273 SEPARATION TO 0.4 MILE SOUTH OF CHURN CREEK ROAD OVERCROSSING
QA Service Level1 (Verified on 12/31/2018)

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

Sample Information

Sample Taken Date12/23/2020 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing12/28/2020 Sample typeQuality Assurance
A brief description of the sample#10 HRC 120 T heads The quantity of what the sample constitutes20
From where was the sample collectedManufacturer First name of sampler or witnessed bySteve
Last name of sampler or witnessed byHall Title of sampler
Telephone number of sampler6466327821 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameHeaded Reinforcement Corp, Fountain Valley, CA
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL134-297-20
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)3100629 Head Manufacturer Lot Number(s)1
Rebar Size#10 Headed Bar Model NameHRC 120
Size of HeadFull Size - 9x Head Connection TypeFriction Weld
Head ShapeSquare Rebar ManufacturerCMC Rancho Cucamonga
Head ManufacturerHeaded Reinforcement Corp Head FabricatorHRC Fountain Valley
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2020-12-23-2-1ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory01/04/202101/04/2021
Yes
01/04/2021OK NeckingPublic - Test Data Visible
2020-12-23-2-2ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory01/04/202101/04/2021
Yes
01/04/2021OK NeckingPublic - Test Data Visible
2020-12-23-2-3ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory01/04/202101/04/2021
Yes
01/04/2021OK NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2020-12-23-2-1 ASTM A970-15e1 (Verified)
DIME Test ID: 2020-12-23-2-2 ASTM A970-15e1 (Verified)
DIME Test ID: 2020-12-23-2-3 ASTM A970-15e1 (Verified)