Sample Record

DIME Sample ID 2020-12-10-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214579
DEA: 010B0904
EFIS: 0100020444
DIST-CO-RTE-PM01-DN-101-8.2/8.7
Award Date04/21/2020
Closeout Date12/02/2025
Work DescriptionPanther Creek & Hunter Creek Bridges
Location DescriptionDEL NORTE COUNTY NEAR KLAMATH AT PANTHER CREEK BRIDGE AND AT HUNTER CREEK BRIDGE
QA Service Level1 (Verified on 03/02/2020)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date12/10/2020 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing12/11/2020 Sample typeQuality Assurance
A brief description of the sampleHRC 500-510 The quantity of what the sample constitutes24
From where was the sample collectedFabricator First name of sampler or witnessed bySherri
Last name of sampler or witnessed byBrannon Title of samplerMETS QA inspector
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCMC Rebar HRC
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC Rebar
Coupler ManufacturerHRC CMC Rebar Intermediate Assembler or Fabricatorx
Rebar Size#8 Coupler Model500-510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)73112579 189111 Rebar Heat Number(s)3099893
Rebar Size 2 8 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2020-12-10-1-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory12/11/202012/11/2020
Yes
12/14/2020OK NeckingPublic - Test Data Visible
2020-12-10-1-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory12/11/202012/11/2020
Yes
12/14/2020OK NeckingPublic - Test Data Visible
2020-12-10-1-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory12/11/202012/11/2020
Yes
12/14/2020OK NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2020-12-10-1-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2020-12-10-1-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2020-12-10-1-3 CTM 670-December 2013 (Verified)