Sample Record
DIME Sample ID 2020-10-22-7
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 209520 DEA: 06470904 EFIS: 0600000973 COOP: 061529 |
|---|---|
| DIST-CO-RTE-PM | 06-MAD-99-R7.5/15.1 |
| Award Date | 03/14/2019 |
| Closeout Date | 05/11/2023 |
| Work Description | WIDEN FREEWAY FROM 4 LANES TO 6 LANES. |
| Location Description | MADERA COUNTY IN AND NEAR MADERA FROM AVENUE 12 OVERCROSSING TO 0.9 MILE NORTH OF AVENUE 17 OVERCROSSING |
| QA Service Level | 1 (Verified on 03/16/2016) |
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Information
| Sample Taken Date | 10/22/2020 | Sample Unique Key | 7 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/30/2020 | Sample type | Quality Assurance |
| A brief description of the sample | Anchor Bolt Hardware | The quantity of what the sample constitutes | 810 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | David |
| Last name of sampler or witnessed by | Lund | Title of sampler | CT METS QA INSPECTOR |
| Telephone number of sampler | 1-385-447-0624 | Laboratory sample identification | na |
| Linked DIME Sample ID | na | The fabricator/manufacturer/facility name | Universal Industrial Sales |
| Transportation Laboratory (TL) Number | na | Inspector Lot Number from the Transportation Laboratory (TL) Form | na |
| Structure unique identifier | Structure name | na | |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | na |
|---|---|---|---|
| Heat Number(s) | 201548 | Nut Mfg. Lot Number(s) | DECN |
| Washer Mfg. Lot Number(s) | na | Bolt Specification | na |
| Bolt Length(s) | na | Nut Specification | A563-DH |
| Washer Specification | na | Finish | Plain |
| Diameter/Size | 2-1/2" | Bolt Mfg. Lot Number | na |
| Rocap Test Requirement(s) | na | Lubricant Requirements(s) | na |
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2020-10-22-7-1 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-10-22-7-2 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-10-22-7-3 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-10-22-7-4 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-10-22-7-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-10-22-7-6 ASTM E18-15 (Verified)
DIME Test ID: 2020-10-22-7-7 ASTM E18-15 (Verified)
DIME Test ID: 2020-10-22-7-8 ASTM E18-15 (Verified)