Sample Record
Owner Lab
- CT HQ - QASI Los Angeles Field Office
DIME Sample ID 2020-10-07-1
Project Information
| Project Identifiers | Project ID: 213741 DEA: 07325704 EFIS: 0716000089 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-5-1.7 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | BUILDING CONSTRUCTION IN LOS ANGELES COUNTY IN SANTA FE SPRINGS AT 14044 FREEWAY DRIVE. |
| Location Description | Santa Fe Springs, At 14044 Freeway Drive. |
| QA Service Level | 1 (Verified on 07/08/2019) |
Sample Information
| Sample Taken Date | 10/07/2020 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 10/12/2020 |
| Sample type | Quality Assurance | A brief description of the sample | ASTM F3125 Type 1 Plain Bolts |
| The quantity of what the sample constitutes | 12 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Arthur | Last name of sampler or witnessed by | Peterson |
| Title of sampler | QA Inspector | Telephone number of sampler | 707-342-8602 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Facilities Engineering | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L110-201-20 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | NA |
|---|---|---|---|
| Heat Number(s) | 100104485 | Nut Mfg. Lot Number(s) | 436800A |
| Washer Mfg. Lot Number(s) | 0420-454 | Bolt Specification | ASTM A325/F3125 |
| Bolt Length(s) | 2-1/2" | Nut Specification | ASTM A194 |
| Washer Specification | F436 | Finish | Plain |
| Diameter/Size | 3/4 - 10 | Bolt Mfg. Lot Number | 440597B |
| Rocap Test Requirement(s) | NA | Lubricant Requirements(s) | NA |
| Washer Inner Diameter(s) |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2020-10-07-1-1 ASTM F606-14a (Verified)
DIME Test ID: 2020-10-07-1-2 ASTM F606-14a (Verified)
DIME Test ID: 2020-10-07-1-3 ASTM F606-14a (Verified)
DIME Test ID: 2020-10-07-1-4 ASTM F606-14a (Verified)
DIME Test ID: 2020-10-07-1-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-10-07-1-6 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-10-07-1-7 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-10-07-1-8 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-10-07-1-9 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-10-07-1-10 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-10-07-1-11 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-10-07-1-12 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-10-07-1-13 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-10-07-1-14 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-10-07-1-15 ASTM E18-15 (Verified)
DIME Test ID: 2020-10-07-1-16 ASTM E18-15 (Verified)
DIME Test ID: 2020-10-07-1-17 ASTM E18-15 (Verified)