Sample Record
DIME Sample ID 2020-09-29-11
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 215113 DEA: 021J2404 EFIS: 0220000048 |
|---|---|
| DIST-CO-RTE-PM | 02-SHA,VAR-273,Var-Var |
| Award Date | 12/02/2019 |
| Closeout Date | 05/23/2022 |
| Work Description | PSPS Streetlight Backing plates-Steel Cantilever structure for solar panels |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 08/17/2020) |
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Information
| Sample Taken Date | 09/29/2020 | Sample Unique Key | 11 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/02/2020 | Sample type | Quality Assurance |
| A brief description of the sample | 3/4"X8 domestic HDG ASTM F1554 hex head bolts with 4" threads. | The quantity of what the sample constitutes | 16 |
| From where was the sample collected | Distributor | First name of sampler or witnessed by | Roland |
| Last name of sampler or witnessed by | Maynard | Title of sampler | QA Inspector |
| Telephone number of sampler | (51) 774-1269 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Portland Bolt | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | S64-006-20 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 1202021930 | Nut Mfg. Lot Number(s) | NA |
| Washer Mfg. Lot Number(s) | NA | Bolt Specification | ASTM F1554 |
| Bolt Length(s) | 8 | Nut Specification | NA |
| Washer Specification | NA | Finish | HDG |
| Diameter/Size | 3/4" | Bolt Mfg. Lot Number | 120202193061 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | NA | |
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2020-09-29-11-1 ASTM F606-14 (Verified)
DIME Test ID: 2020-09-29-11-2 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-09-29-11-3 ASTM B499-14 (Verified)