Sample Record
Owner Lab
- CT HQ - QASI Bay Area Field Office
DIME Sample ID 2014-01-09-11005465
Project Information
| Project Identifiers | Project ID: 7531 DEA: 042908C4 EFIS: 0400021248 COOP: 042397A3 |
|---|---|
| DIST-CO-RTE-PM | 04-ALA-580-R8.4/R14.6 |
| Award Date | 11/20/2012 |
| Closeout Date | 09/30/2016 |
| Work Description | ROADWAY WIDENING AND REHABILITATION. |
| Location Description | ALAMEDA COUNTY IN LIVERMORE FROM 0.1 MILE WEST OF GREENVILLE ROAD UNDERCROSSING TO 0.5 MILE WEST OF 84/580 SEPARATION |
| QA Service Level | 1 (Verified on 09/24/2012) |
Sample Information
| Sample Taken Date | 01/09/2014 | Sample Unique Key | 11005465 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 01/13/2014 |
| Sample type | Informational | A brief description of the sample | Precast Concrete Pavement Panel |
| The quantity of what the sample constitutes | 6x12 Cylinders | From where was the sample collected | Source |
| First name of sampler or witnessed by | Ryan | Last name of sampler or witnessed by | Cummings |
| Title of sampler | QA Inspector | Telephone number of sampler | Not set |
| Laboratory sample identification | Not set | Linked DIME Sample ID | Not set |
| The fabricator/manufacturer/facility name | ConFab | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
| Structure name | PCP | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | V80-25FP |
|---|---|---|---|
| The truck number from where the sample was collected | Not set | The batch plant ticket number from where the sample was collected | unknown |
| Concrete batch plant | Not set | The fabricator/manufacturer designation for the sample | Not set |
| A detailed description of where the material sample was collected | By formwork at precast plant during pour inspection | Where the material sample would have been placed if not sampled | Not set |
| From Lot No. | Not set | Bag Lot No. | Not set |
Submitted Tests
| DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Date Added | Verified? | Release Date | Test Comments | Privacy Level | Actions |
|---|---|---|---|---|---|---|---|---|---|
| 2014-01-09-11005465-1 | ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens | Stanley Mak, CT HQ - Vallejo Field Laboratory | 01/16/2014 | No |
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2014-01-09-11005465-1 ASTM C39-10