Sample Record
DIME Sample ID 2014-01-10-12003633
Project Information
| Project Identifiers | Project ID: 208572 DEA: 100L3304 EFIS: 1000000100 COOP: 10355 Permit Numbers: 1012NMC0508 |
|---|---|
| DIST-CO-RTE-PM | 10-STA-99-0.0/0.3 |
| Award Date | Not set |
| Closeout Date | 03/09/2020 |
| Work Description | Reconsteuct SR99/Kiernan Interchange |
| Location Description | City of Salida, in STA County |
| QA Service Level | 1 (Verified on 03/25/2013) |
Owner Lab
- CT HQ - QASI Bay Area Field Office
Sample Information
| Sample Taken Date | 01/10/2014 | Sample Unique Key | 12003633 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 01/13/2014 | Sample type | Informational |
| A brief description of the sample | Mix Design K6090-621SCC | The quantity of what the sample constitutes | 2 concrete cylinders |
| From where was the sample collected | Source | First name of sampler or witnessed by | Ricardo |
| Last name of sampler or witnessed by | Medina | Title of sampler | QA Inspector |
| Telephone number of sampler | Not set | Laboratory sample identification | Not set |
| Linked DIME Sample ID | Not set | The fabricator/manufacturer/facility name | KieCon |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Not set | Structure name | PCPS Wide Flange Girder No. G1A |
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | K6090-621SCC |
|---|---|---|---|
| The truck number from where the sample was collected | Not set | The batch plant ticket number from where the sample was collected | 53108 |
| Concrete batch plant | Not set | The fabricator/manufacturer designation for the sample | KieCon |
| A detailed description of where the material sample was collected | By formwork at precast plant during pour inspection | Where the material sample would have been placed if not sampled | Not set |
| From Lot No. | Not set | Bag Lot No. | Not set |
Submitted Tests
| DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Date Added | Verified? | Release Date | Test Comments | Privacy Level | Actions |
|---|---|---|---|---|---|---|---|---|---|
| 2014-01-10-12003633-1 | ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens | William Sommer, CT HQ - Vallejo Field Laboratory | 01/17/2014 | No | Specimen unbroken. Loaded to peak to avoid overload (10ksi) |
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2014-01-10-12003633-1 ASTM C39-10