Sample Record

DIME Sample ID 2020-08-11-17

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214654
DEA: 020J1904
EFIS: 0219000070
DIST-CO-RTE-PM02-LAS-395-R114.5/119.0
Award Date04/02/2020
Closeout Date10/22/2020
Work DescriptionPLACE HMA (TYPE A) OVERLAY, SHOULDER BACKING, AND TRAFFIC STRIPE.
Location DescriptionLASSEN COUNTY AT AND NEAR TERMO FROM 4.2 MILES NORTH OF CEMETERY ROAD TO 1.6 MILES SOUTH OF COUNTY ROAD 531
QA Service Level1 (Verified on 03/02/2020)

Owner Lab

  • CT HQ - Sacramento Asphalt Binder Laboratory

Sample Information

Sample Taken Date08/11/2020 Sample Unique Key17
Date that the sample was received by the laboratory/organization performing the testing08/19/2020 Sample typeDepartment Acceptance
A brief description of the sampleAB #1 test received 1st sample, #2(996931), #3(891905) No Test The quantity of what the sample constitutes1
From where was the sample collectedSource First name of sampler or witnessed byj
Last name of sampler or witnessed bydelejade Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameEagle Peak
Transportation Laboratory (TL) Number897714 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-28 M
ModifiedYes Lot number
Sublot number Tank numberNot set
Time of sampleNot set HMA SupplierNot set
Certified Asphalt SupplierNot set MultigradeNot set
Multigrade TypeNot set Asphalt Binder Mix NumberNot set
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2020-08-11-17-1AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)Ruben Macias, CT HQ - Sacramento Asphalt Binder Laboratory08/20/2020
Yes
09/18/2020Public - Test Data Visible
2020-08-11-17-2AASHTO T301-13: Standard Method of Test for Elastic Recovery Test of Asphalt Materials by Means of a DuctilometerRuben Macias, CT HQ - Sacramento Asphalt Binder Laboratory09/22/2020
Yes
09/29/2020Public - Test Data Visible
2020-08-11-17-3AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)Eva Torres, CT HQ - Sacramento Asphalt Binder Laboratory09/18/2020
Yes
09/21/202070deg 2.89 kpa Phase angle = 66Public - Test Data Visible
2020-08-11-17-4AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)Xavier Carrillo, CT HQ - Sacramento Asphalt Binder Laboratory09/16/2020
Yes
09/21/2020Public - Test Data Visible
2020-08-11-17-5AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)Doug Ruff, CT HQ - Sacramento Asphalt Binder Laboratory09/22/2020
Yes
09/25/2020Public - Test Data Visible
2020-08-11-17-6AASHTO T313-19: Standard Method of Test for Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)Sunday Agude, CT HQ - Sacramento Asphalt Binder Laboratory09/28/2020
Yes
09/29/2020Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2020-08-11-17-1 AASHTO T240-17 (Verified)
DIME Test ID: 2020-08-11-17-2 AASHTO T301-13 (Verified)
DIME Test ID: 2020-08-11-17-3 AASHTO T315-16 (Verified)
DIME Test ID: 2020-08-11-17-4 AASHTO T315-16 (Verified)
DIME Test ID: 2020-08-11-17-5 AASHTO T315-16 (Verified)
DIME Test ID: 2020-08-11-17-6 AASHTO T313-19 (Verified)