Sample Record

DIME Sample ID 2020-08-06-7

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214841
DEA: 034H1004
EFIS: 0318000176
DIST-CO-RTE-PM03-SIE-49-9.2/24.7
Award Date05/29/2020
Closeout Date07/29/2022
Work DescriptionINSTALL RETAINING STRUCTURE AND RSP CONCRETE EMBANKMENT.
Location DescriptionSIERRA COUNTY ON ROUTE 49 AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 03/24/2020)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date08/06/2020 Sample Unique Key7
Date that the sample was received by the laboratory/organization performing the testing08/07/2020 Sample typeQuality Assurance
A brief description of the sampleBarsplice Zap Screwlok Coupler The quantity of what the sample constitutes4
From where was the sample collectedJob Site First name of sampler or witnessed byJ
Last name of sampler or witnessed byRoss Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameNucor Erico
Transportation Laboratory (TL) NumberC695451 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerBarSplice Intermediate Assembler or Fabricator
Rebar Size#10 Coupler ModelZap Screwlok
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)A200695 Rebar Heat Number(s)3500009225
Rebar Size 2 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2020-08-06-7-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory08/07/202008/07/2020
Yes
08/07/2020Service SplicePublic - Test Data Visible
2020-08-06-7-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory08/07/202008/07/2020
Yes
08/07/2020Service SplicePublic - Test Data Visible
2020-08-06-7-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory08/07/202008/07/2020
Yes
08/07/2020Service SplicePublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2020-08-06-7-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2020-08-06-7-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2020-08-06-7-3 CTM 670-December 2013 (Verified)