Sample Record
DIME Sample ID 2020-04-14-37
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 214492 DEA: 033F5404 EFIS: 0313000136 |
|---|---|
| DIST-CO-RTE-PM | 03-SAC-99,160-4.5/5.7,R44.5 |
| Award Date | 01/24/2020 |
| Closeout Date | 07/28/2022 |
| Work Description | FURNISH PRECAST PRESTRESSED CONCRETE SLAB & PLACE STRUCTURAL CONCRETE. |
| Location Description | SACRAMENTO COUNTY NEAR GALT ON ROUTE 99 FROM NORTH OF MINGO ROAD TO SOUTH OF ARNO ROAD OVERCROSSING AND IN SACRAMENTO ON ROUTE 160 AT AMERICAN RIVER BRIDGE |
| QA Service Level | 1 (Verified on 10/23/2019) |
Owner Lab
- CT D03 - Olivehurst Northern Regional Laboratory
Sample Information
| Sample Taken Date | 04/14/2020 | Sample Unique Key | 37 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 04/24/2020 | Sample type | Verification |
| A brief description of the sample | Hot Bin Samples for JMF | The quantity of what the sample constitutes | JMF 4 bags |
| From where was the sample collected | Source | First name of sampler or witnessed by | Walter |
| Last name of sampler or witnessed by | Wylie | Title of sampler | TET |
| Telephone number of sampler | Laboratory sample identification | JMF20-014 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Teichert Perkins | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-34-0045::ASPEN IV SOUTH |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Hot Bins | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
| The concrete mix design number | JMF20-014 | Lot number | |
| Sublot number | Aggregate Mix Number | Not set |
JMF Information
| Verification ID | JMF3513-2020-175 | Date Created | 08/04/2020 |
|---|---|---|---|
| JMF Submittal ID | JMF3511-23-2020-257 | JMF Status | Submittal Accepted for Verification |
| Producer Mix ID | PN202004-SP | Authorized Date | N/A |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2020-04-14-37-1 AASHTO T27-14 (Verified)
DIME Test ID: 2020-04-14-37-2 AASHTO T335-09r13 (Verified)
DIME Test ID: 2020-04-14-37-3 AASHTO T85-13 (Verified)
DIME Test ID: 2020-04-14-37-4 AASHTO T96-02r10 (Verified)
DIME Test ID: 2020-04-14-37-5 AASHTO T84-14 (Verified)
DIME Test ID: 2020-04-14-37-6 AASHTO T304-11 (Verified)
DIME Test ID: 2020-04-14-37-8 AASHTO T176-08 (Verified)