Sample Record
DIME Sample ID 2020-06-23-8
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 214422 DEA: 040J6424 EFIS: 0414000476 |
|---|---|
| DIST-CO-RTE-PM | 04-SON-101-32.8/R54.2 |
| Award Date | 12/24/2019 |
| Closeout Date | 01/03/2025 |
| Work Description | CRACK, SEAT AND OVERLAY WITH RHMA AND HMA, AND REPLACE CULVERTS. |
| Location Description | SONOMA COUNTY AT VARIOUS LOCATIONS FROM LIMERICK LANE OVERCROSSING TO ROUTE 101/128 SEPARATION |
| QA Service Level | 1 (Verified on 09/23/2019) |
Owner Lab
- Con-Fab California Corporation - Lathrop
Sample Information
| Sample Taken Date | 06/23/2020 | Sample Unique Key | 8 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/24/2020 | Sample type | Quality Control |
| A brief description of the sample | 6x12 concrete cylinders | The quantity of what the sample constitutes | 2 6x12 Cylinders |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Mark Patrick |
| Last name of sampler or witnessed by | Baddu | Title of sampler | QC Inspector |
| Telephone number of sampler | Laboratory sample identification | 6-23-20-B4 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Con-Fab California, LLC | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | State Route 101 | |
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | VER-85LV |
|---|---|---|---|
| The truck number from where the sample was collected | 2nd | The batch plant ticket number from where the sample was collected | 193 |
| Concrete batch plant | BP3 | The fabricator/manufacturer designation for the sample | Unknown |
| A detailed description of where the material sample was collected | Bed 4, 2nd Truck | Where the material sample would have been placed if not sampled | Casting Bed |
| From Lot No. | Unknown | Bag Lot No. | Unknown |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2020-06-23-8-1 ASTM C39-10 (Verified)