Sample Record
Owner Lab
- Trinity Engineering Laboratories, Incorporated - Fresno
DIME Sample ID 2013-11-19-8009909
Project Information
Project Identifiers | Project ID: 10016 DEA: 06342524 EFIS: 0600000381 |
---|---|
DIST-CO-RTE-PM | 06-FRE-180-R71.8/74.5 |
Award Date | 04/23/2013 |
Closeout Date | 10/19/2020 |
Work Description | NEW EXPRESS HIGHWAY |
Location Description | FRESNO COUNTY ABOUT 6.3 MILES EAST OF FRESNO FROM 0.6 MILE WEST OF QUALITY AVENUE TO 0.2 MILE WEST OF SMITH AVENUE |
QA Service Level | 1 (Verified on 07/23/2013) |
Sample Information
Sample Taken Date | 11/19/2013 | Sample Unique Key | 8009909 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/19/2013 |
Sample type | Quality Control | A brief description of the sample | 1x4 |
The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Source |
First name of sampler or witnessed by | Alan | Last name of sampler or witnessed by | Oliver |
Title of sampler | Lab Technician | Telephone number of sampler | (559) 292-2188 |
Laboratory sample identification | 2013-11-19-0820-1 | Linked DIME Sample ID | Not set |
The fabricator/manufacturer/facility name | Builders Concrete Ready Mix Plant Sanger | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-10-0010 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Builders Concrete Ready Mix Plant Sanger | The fabricator/manufacturer designation for the sample | Builders Concrete Ready Mix Plant Sanger |
The plant number | 111 | A detailed description of where the material sample was collected | conveyor belt |
Where the material sample would have been placed if not sampled | stockpiles | Primary Aggregate Nominal Size | |
The concrete mix design number | Lot number | Not set | |
Sublot number | Not set | Aggregate Mix Number | Not set |
Submitted Tests
DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
---|---|---|---|---|---|---|---|---|
2013-11-19-8009909-1 | ASTM C136-06: Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates | Doug Lade, Trinity Engineering Laboratories, Incorporated - Fresno | 11/20/2013 | Doug Lade | No | Info | ||
2013-11-19-8009909-2 | AASHTO T11-5: Standard Method of Test for Materials Finer Than 75-μm (No. 200) Sieve in Mineral Aggregates by Washing | Doug Lade, Trinity Engineering Laboratories, Incorporated - Fresno | 11/20/2013 | Doug Lade | No | Info | ||
2013-11-19-8009909-3 | AASHTO T255-0: Standard Method of Test for Total Evaporable Moisture Content of Aggregate by Drying | Doug Lade, Trinity Engineering Laboratories, Incorporated - Fresno | 11/20/2013 | Doug Lade | No | Info |
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2013-11-19-8009909-1 ASTM C136-06
DIME Test ID: 2013-11-19-8009909-2 AASHTO T11-5
DIME Test ID: 2013-11-19-8009909-3 AASHTO T255-0