Sample Record
DIME Sample ID 2020-04-03-1
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 211848 DEA: 112T2174 EFIS: 1116000131 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-5-R37.4 - R46.5 |
| Award Date | 12/22/2016 |
| Closeout Date | 05/01/2026 |
| Work Description | (Alternative Delivery) CMGC, San Elijo Highway Bridge Replacement. Replace the San Elijo lagoon highway bridge, construct HOV lanes, construct bike and pedestrian trails and bridge, build multi-use facility at Manchester Ave. |
| Location Description | IN SAN DIEGO COUNTY IN SOLANA BEACH AND ENCINITAS FROM 0.1 MILE NORTH OF LOMAS SANTA FE DRIVE OVERCROSSING TO 0.2 MILE SOUTH OF BIRMINGHAM DRIVE OVERCROSSING |
| QA Service Level | 1 (Verified on 01/31/2017) |
Owner Lab
- CT - Unassigned/General Field Laboratory
Sample Information
| Sample Taken Date | 04/03/2020 | Sample Unique Key | 1 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 04/09/2020 | Sample type | Quality Assurance |
| A brief description of the sample | HRC 500/510 | The quantity of what the sample constitutes | 48 |
| From where was the sample collected | Source | First name of sampler or witnessed by | Mike |
| Last name of sampler or witnessed by | Kopenski | Title of sampler | QA Inspector |
| Telephone number of sampler | 310-745-9655 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | CMC San Bernardino | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | L149-008-20 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | CMC Steel California |
| Coupler Manufacturer | HRC | Intermediate Assembler or Fabricator | |
| Rebar Size | 11 | Coupler Model | 500/510 |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
| Coupler Component Heat/Lot Number(s) | 73113004 / 74115534 | Rebar Heat Number(s) | 1063859 3093500 3092873 |
| Rebar Size 2 | 11 | Coupler Unique ID | Not set |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2020-04-03-1-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2020-04-03-1-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2020-04-03-1-3 CTM 670-December 2013 (Verified)