Sample Record

DIME Sample ID 2020-03-18-7

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214190
DEA: 024G41U4
EFIS: 0218000047
DIST-CO-RTE-PM02-SIS,SIS-5-Var
Award Date08/26/2019
Closeout Date11/24/2021
Work DescriptionREPLACE REINFORCED CONCRETE BRIDGES & CONSTRUCT RETAINING WALL.
Location DescriptionSHASTA AND SISKIYOU COUNTIES ABOUT 7 MILES NORTH OF POLLARD FLAT FROM 0.8 MILE SOUTH TO 0.7 MILE NORTH OF SIMS ROAD UNDERCROSSING AND FROM 0.6 MILE SOUTH OF CASTLE CRAGS DRIVE UNDERCROSSING TO 0.2 MILE SOUTH OF SOUTH DUNSMUIR UNDERCROSSING
QA Service Level1 (Verified on 07/09/2019)

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

Sample Information

Sample Taken Date03/18/2020 Sample Unique Key7
Date that the sample was received by the laboratory/organization performing the testing03/24/2020 Sample typeQuality Assurance
A brief description of the sample#8 Rebar with HRC 150 T Head The quantity of what the sample constitutes48
From where was the sample collectedFabricator First name of sampler or witnessed byChris
Last name of sampler or witnessed byDsouza Title of sampler
Telephone number of sampler6469423585 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameHRC Fountain Valley
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)1202016630 Head Manufacturer Lot Number(s)Lot 1
Rebar Size8 Headed Bar Model NameHRC 150
Size of HeadFull Size - 9x Head Connection TypeFriction Weld
Head ShapeSquare Rebar ManufacturerNucor
Head ManufacturerHRC Head FabricatorHRC
Material Standard CodeASTM A615 Headed Bar Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2020-03-18-7-1ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory03/25/202003/25/2020
Yes
03/25/2020OK NeckingPublic - Test Data Visible
2020-03-18-7-2ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory03/25/202003/25/2020
Yes
03/25/2020OK NeckingPublic - Test Data Visible
2020-03-18-7-3ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory03/25/202003/25/2020
Yes
03/25/2020OK NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2020-03-18-7-1 ASTM A970-15e1 (Verified)
DIME Test ID: 2020-03-18-7-2 ASTM A970-15e1 (Verified)
DIME Test ID: 2020-03-18-7-3 ASTM A970-15e1 (Verified)