Sample Record

DIME Sample ID 2020-03-11-4

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 212324
DEA: 033F5104
EFIS: 0313000020
DIST-CO-RTE-PM03-YUB-20-R18.1/R20.1
Award Date10/31/2019
Closeout Date08/03/2023
Work DescriptionConstruct bridge, realign curve & widen shoulders.
Location DescriptionConstruction on state highway in Yuba County near Smartsville from the Yuba River Bridge to 0.3 mile east of Smartsville Road.
QA Service Level1 (Verified on 02/27/2020)

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

Sample Information

Sample Taken Date03/11/2020 Sample Unique Key4
Date that the sample was received by the laboratory/organization performing the testing03/11/2020 Sample typeQuality Assurance
A brief description of the sample(4) #8 Hoops 6'-8" Ø The quantity of what the sample constitutes4
From where was the sample collectedFabricator First name of sampler or witnessed byRigoberto
Last name of sampler or witnessed byMarin Title of samplerQAI
Telephone number of sampler951-500-0685 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameTNT Rebar
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL133-054-20
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)PL17207176
Hoop Manufacturer Lot Number(s)Lot 14 Material Standard CodeASTM A706
Material Grade60 Rebar Size8
Diameter of Hoop6'-8" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2020-03-11-4-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory03/18/202003/18/2020
Yes
03/18/2020Ok NeckingPublic - Test Data Visible
2020-03-11-4-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory03/18/202003/18/2020
Yes
03/18/2020Ok NeckingPublic - Test Data Visible
2020-03-11-4-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory03/18/202003/18/2020
Yes
03/18/2020Ok NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2020-03-11-4-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2020-03-11-4-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2020-03-11-4-3 CTM 670-December 2013 (Verified)