Sample Record
Owner Lab
- CT D08 - Fontana Southern Regional Laboratory
DIME Sample ID 2020-02-20-10
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 213746 DEA: 080Q75U4 EFIS: 0817000114 |
---|---|
DIST-CO-RTE-PM | 08-SBD,RIV-60-R4.6/R9.9, R0.0/12.2 |
Award Date | 04/18/2019 |
Closeout Date | 06/28/2022 |
Work Description | REPLACEMENT OF TWO OUTSIDE LANES AND CONCRETE SLABS |
Location Description | Not set |
QA Service Level | 1 (Verified on 06/17/2019) |
Sample Information
Sample Taken Date | 02/20/2020 | Sample Unique Key | 10 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/25/2020 |
Sample type | Quality Assurance | A brief description of the sample | 6x12 LCB cylinders |
The quantity of what the sample constitutes | 6 cylinders | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Ronnie | Last name of sampler or witnessed by | Roberts |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 999-220B | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | NA | Transportation Laboratory (TL) Number | 999-220B |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | LCB-60 |
---|---|---|---|
The truck number from where the sample was collected | NA | The batch plant ticket number from where the sample was collected | NA |
Concrete batch plant | NA | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | Job Site | Where the material sample would have been placed if not sampled | EB RTE 60 EAST OF VINEYARD AVE ON RAMP LANE 5 |
From Lot No. | Unknown | Bag Lot No. | Unknown |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2020-02-20-10-1 ASTM C39-17a (Verified)