Sample Record
Owner Lab
- Signet Testing Laboratories - Anaheim
DIME Sample ID 2013-07-16-13205615
Project Information
Project Identifiers | Project ID: 7780 DEA: 112T1824 EFIS: 1100020051 |
---|---|
DIST-CO-RTE-PM | 11-SD-805-4.7/5.6 |
Award Date | 01/03/2013 |
Closeout Date | 09/07/2018 |
Work Description | REPLACE STRUCTURE AND CONSTRUCT DIRECT ACCESS RAMP (DAR). |
Location Description | SAN DIEGO COUNTY IN CHULA VISTA FROM 0.4 MILE SOUTH OF EAST PALOMAR STREET OVERCROSSING TO 0.1 MILE NORTH OF NAPLES STREET UNDERCROSSING |
QA Service Level | 1 (Verified on 12/10/2012) |
Sample Information
Sample Taken Date | 07/16/2013 | Sample Unique Key | 13205615 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/17/2013 |
Sample type | Quality Control | A brief description of the sample | 6x12 concrete cylinders |
The quantity of what the sample constitutes | 4 cylinders | From where was the sample collected | Source |
First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Engler |
Title of sampler | Not set | Telephone number of sampler | Not set |
Laboratory sample identification | 2013-07-16-1320 | Linked DIME Sample ID | Not set |
The fabricator/manufacturer/facility name | Vulcan | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Concrete | The concrete mix design number | 103612F |
---|---|---|---|
The truck number from where the sample was collected | Not set | The batch plant ticket number from where the sample was collected | 20 |
Concrete batch plant | Not set | The fabricator/manufacturer designation for the sample | Not set |
A detailed description of where the material sample was collected | Sound Wall Footing sta 13 15 | Where the material sample would have been placed if not sampled | Not set |
From Lot No. | Not set | Bag Lot No. | Not set |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2013-07-16-13205615-1 ASTM C138-10b (Verified)
DIME Test ID: 2013-07-16-13205615-2 ASTM C143-10a (Verified)
DIME Test ID: 2013-07-16-13205615-3 ASTM C1064-08 (Verified)
DIME Test ID: 2013-07-16-13205615-4 CTM 521-June 2012 (Verified)
DIME Test ID: 2013-07-16-13205615-5 ASTM C39-10 (Verified)
DIME Test ID: 2013-07-16-13205615-6 CTM 521-June 2012 (Verified)