Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2020-01-30-29
Project Information
| Project Identifiers | Project ID: 99999 DEA: 0322222 |
|---|---|
| DIST-CO-RTE-PM | 03-SAC,OMG-888,99,80-0.6-0.6 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
| Location Description | THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
| QA Service Level | (Verified on 04/05/2013) |
Sample Information
| Sample Taken Date | 01/30/2020 | Sample Unique Key | 29 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/05/2020 |
| Sample type | Authorization | A brief description of the sample | #6 Barsplice XP |
| The quantity of what the sample constitutes | 4 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Benjamin | Last name of sampler or witnessed by | Marotta |
| Title of sampler | Engineering Manager | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Barsplice | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Service or Ultimate | Service | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | CMC |
| Coupler Manufacturer | Barsplice | Intermediate Assembler or Fabricator | Unknown |
| Rebar Size | 6 | Coupler Model | Barsplice Xp |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
| Coupler Component Heat/Lot Number(s) | 100796226 | Rebar Heat Number(s) | 7005883 |
| Rebar Size 2 | 6 | Coupler Unique ID | Not set |
Submitted Tests
| DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Date Added | Verified? | Release Date | Test Comments | Privacy Level | Actions |
|---|---|---|---|---|---|---|---|---|---|
| 2020-01-30-29-1 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip) | fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory | 06/17/2020 | 06/17/2020 | No | Service Splice 10K Cycle | |||
| 2020-01-30-29-2 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip) | fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory | 06/17/2020 | 06/17/2020 | No | Service Splice 100 Cycle | |||
| 2020-01-30-29-3 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip) | fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory | 06/17/2020 | 06/17/2020 | No | Service Splice | |||
| 2020-01-30-29-4 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip) | fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory | 06/17/2020 | 06/17/2020 | No | Service Splice |
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2020-01-30-29-1 CTM 670-December 2013
DIME Test ID: 2020-01-30-29-2 CTM 670-December 2013
DIME Test ID: 2020-01-30-29-3 CTM 670-December 2013
DIME Test ID: 2020-01-30-29-4 CTM 670-December 2013