Sample Record

DIME Sample ID 2020-01-07-9

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214666
DEA: 022H8104
EFIS: 0217000012
DIST-CO-RTE-PM02-TRI-299-1.67/45.12
Award Date03/03/2022
Closeout Date08/11/2023
Work DescriptionTRINITY CULVERTS
Location DescriptionCULVERT REHABILITATION IN TRINITY COUNTY NEAR SALYER AT VARIOUS LOCATIONS FROM 0.1 MILE WEST OF WHITE HOUSE GULCH ROAD TO 0.4 MILE WEST OF SLATTERY POND ROAD.
QA Service Level1 (Verified on 03/02/2020)

Owner Lab

  • CT D02 - Redding Northern Regional Laboratory

Sample Information

Sample Taken Date01/07/2020 Sample Unique Key9
Date that the sample was received by the laboratory/organization performing the testing01/09/2020 Sample typePreliminary
A brief description of the sampleSoil for Use in Fill The quantity of what the sample constitutesPreliminary Design
From where was the sample collectedJob Site First name of sampler or witnessed byScott
Last name of sampler or witnessed byLewis Title of samplerEngineering Geologist
Telephone number of sampler Laboratory sample identificationD78322
Linked DIME Sample ID The fabricator/manufacturer/facility nameIn Situ
Transportation Laboratory (TL) Number678221 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleUnknown
The fabricator/manufacturer designation for the sampleField No. TC-1 A detailed description of where the material sample was collected02-TRI-299-8.19, Embankment on South Side, 6 - 12 inch Depth
Where the material sample would have been placed if not sampledUnknown

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2020-01-07-9-2CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)Dennis Hickey, CT D02 - Redding Northern Regional Laboratory02/07/2020
Yes
02/19/2020Public - Test Data Visible
2020-01-07-9-3CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and WaterDarrell Valasek, CT D02 - Redding Northern Regional Laboratory01/21/2020
Yes
02/19/2020Public - Test Data Visible
2020-01-07-9-4CTM 203-February 2008: Mechanical Analysis of SoilsKaren Spliethof and D. Hickey, CT D02 - Redding Northern Regional Laboratory02/07/2020
Yes
02/19/2020Could not get raw data input to produce correct results. Calculated values were input directly.Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2020-01-07-9-2 CTM 204-June 2010 (Verified)
DIME Test ID: 2020-01-07-9-3 CTM 643-June 2007 (Verified)
DIME Test ID: 2020-01-07-9-4 CTM 203-February 2008 (Verified)